Product Datasheets - Alphabetical Listing

Roof Insulation Specifications

 


The JM Insulation Specification numbering system is designed to allow the designer to easily and clearly describe a particular insulation construction. Arabic numerals denote the number of layers of insulation attached in a particular manner. Capital letters indicate the method of attachment of the insulation and the presence of a vapor retarder.

Capital letters indicate the following:
M = Mechanically Attached
A = Adhered
L = Loose Laid
V = Vapor Retarder
C = Cold Adhesive

Examples:

  • A construction of one layer of insulation mechanically attached to a structural deck with a vapor retarder and a second layer of insulation mopped in hot asphalt would be described as 1MV1A.
  • Two layers of insulation in hot asphalt to a structural deck would be described as 2A.
  • One layer of insulation loose laid on a structural deck would be described as 1L.
Deck Substrate: S = Steel
W = Wood
L = Lightweight Concrete
C = Concrete
G = Gypsum
T = Cementitious Wood Fiber
Insulation
Specification
Insulation
Bottom Layer Attachment
Insulation
Top Layer Attachment
Deck Substrate
1MV1A
1M1A
1M1C
1A
2A
1C
1L
1L1M
1M
1MV2A
V1A
V2A
Mech. Attached
Mech. Attached
Mech. Attached
--
Adhered
--
--
Loose Laid
--
Mech. Attached
--
Adhered
Adhered
Adhered
Cold Adhesive
Adhered
Adhered
Cold Adhesive
Loose Laid
Mech. Attached
Mech. Attached
Adhered
Adhered
Adhered
S, W, L, C, G, T
S, W, L, C, G, T
S, W, L, C, G, T
L*, W*, C, G*, T*
L*, W*, C, G*, T*
L*, W*, C, G*, T*
S, W, L, C, G, T
S, W, L, C, G, T
S, W, L, C, G, T
S
W**, L**, C, G**, T**
W**, L**, C, G**, T**

* Insulation must be fully adhered to nailed base sheet.
** Vapor barrier must be adhered to nailed base sheet.